Experimental studies of the vortex hydraulic elevator
Loading...
Date
Journal Title
Journal ISSN
Volume Title
Publisher
Publishing House of the KarSU named after academician E.A. Buketov
Abstract
The article presents the results of experimental studies to assess the optimal operation modes of the
vortex hydraulic elevator of the autonomous water treatment system. Based on experimental studies, it
has been shown that twisting of the working and suction flows significantly increases the ejection
capacity of vortex hydraulic elevators. The analysis of the results obtained (the curves of the dependence
of the ejection coefficient on the spin parameters) allows us to conclude that there are optimal critical
values for the vortex hydraulic elevator and hydraulic elevator with a tangential intake of the intake
medium at which the highest value of the ejection coefficient is reached. It was also revealed that the
swirling active and passive flows radically affect the mechanism for drawing the intake fluid into the
mixing chamber of the hydraulic elevator. An increase in the swirling intensity increases the mixing of
the flow, and large pressure gradients occur not only in the axial but also in the radial direction, which
leads to an increase in the ejection coefficient. Thus, on the basis of the conducted experimental studies
and preliminary technical and economic calculations, it can be concluded that the use of vortex
hydraulic elevators for hydro transportation of various mixtures will significantly reduce energy
consumption and increase the efficiency of their application.
Description
Citation
Experimental studies of the vortex hydraulic elevator/K.E. Sakipov [et al.] //Eurasian Physical Technical Journal. - 2018.- Vol.15 - № 2(30).- P. 89-97.