ENHANCEMENT OF STEAM-TURBINE CONDENSER STEAM-JET EJECTOR
Loading...
Files
Date
Journal Title
Journal ISSN
Volume Title
Publisher
KU Publ.
Abstract
A three-stage steam-jet ejector EPO-3-200 with a working steam flow rate of 850 t / h is installed at the
Combined Heat and Power Plant-2 of the city of Almaty on heating turbines. In this paper, the replacement of the
existing three-stage steam-jet ejector with a two-stage steam-jet ejector is proposed and substantiated. As a result
of the replacement, they obtained a saving of heat (steam) for their own needs for the production of electrical
energy. It has been established that at a pressure in the turbine condenser significantly lower than 100 kPa, it is
advisable to install a new two-stage ejector EPO-2-80 instead of EPO-3-200. Using the existing calculation
methods, the geometric characteristics of the new ejector were obtained. The working steam flow rate of the new
two-stage ejector is 579 t / h. In addition, the use of two stages makes it possible to simplify the design and make it
more reliable, and also makes it possible to increase the pressure in the cooler of the 1st stage of the ejector. This
is especially important for cogeneration turbines, which may have a high temperature of the main condensate,
which adversely affects the performance of a conventional three-stage ejector.
Description
Citation
Shavdinova M.D. ENHANCEMENT OF STEAM-TURBINE CONDENSER STEAM-JET EJECTOR/M.D. Shavdinova, R.Zh. Sharipov, T.Y. Meshherjakova//Eurasian Physical Technical Journal. -2021. №4. Р.52-58.