Saturation of gas concentration signal of the laser gas sensor
Loading...
Date
Journal Title
Journal ISSN
Volume Title
Publisher
Eurasian Physical Technical Journal
Abstract
Nowadays it is possible to determine the type of gas with sufficient accuracy when its concentration
is less than 10−6 fractions using spectroscopic methods (optical, radio engineering, acoustic). Along with this, the
value of permissible concentrations of explosive, toxic, harmful to technology and ecology gases is practically
important. Known physical experimental studies indicate only a linear dependence of the response of a laser gas
sensor at units ≲ 103. The research methods for units ≳ 103 are based on the processes of combustion, microexplosion,
structural and phase transformations and are not always applicable in real practical conditions. The
work is devoted to the analysis of experimentally obtained fluctuations caused by a laser beam in a gas in a
photodiode (signal receiver) due to its influence not only at the atomic level, but also on the scale of clusters of
nanoparticle molecules. The gas concentration is estimated by the fluctuation-dissipation ratio. It is shown that the
signal correlator is saturated to a constant value when the quantum (laser photon energy) and thermal (nanoparticle
temperature) factors are comparable with an increase in the concentration of the target gas. The critical values of
the saturation concentration are determined by the equality of these two factors.
Description
Citation
Saturation of gas concentration signal of the laser gas sensor / Zhanabaev Z.Zh. [et al.] // Eurasian Physical Technical Journal. – 2024. – Vol.21. – № 3(49). – pp. 71-8 0.