Direct contact resistance measurement during thermoelectric testing
Loading...
Date
Journal Title
Journal ISSN
Volume Title
Publisher
Karagandy University of the name of acad. E.A. Buketov
Abstract
The article analyzes the influence of the contact resistance of the electrodes on the inspection
result. It is shown that as the value of the measuring resistor increases, the permissible value of the contact
resistance of the electrodes with the test sample increases. An indirect method for monitoring contact resistance
has been proposed, which consists of passing a stable high-frequency current through the contact resistance and
measuring the voltage across this resistance. The variation of relative voltage across the measuring resistor with
respect to the total contact resistance has been graphed. The maximum allowable contact resistance has been
determined to ensure that the measured thermoelectric EMF differs from the true value by no more than 10%. The
proposed method allows to measure contact resistance directly in the process of monitoring thermoelectromotive
force.
Description
Citation
Direct contact resistance measurement during thermoelectric testing/Soldatov A.I. [et al.] // Eurasian Physical Technical Journal. – 2024- Vol.21 - № 2(48). – pp.38-48.