Abstract
The article presents the results of modeling a multipoint contact in the thermoelectric method of
testing. Sources of thermoelectromotive force (thermoEMF) have shown different influences, according to their
type, on the load characteristics of the equivalent source obtained by parallel connection of several
thermocouples as shown in the explanatory figures. The presented model is implemented in the NI LabVIEW
package, which is freely available. The model was verified on three types of thermocouples (copper-constantan,
copper-nichrome, and chromel-alumel), which have been connected in parallel in different quantities. The
calculated load characteristics of the equivalent sources differ from the experimental ones by no more than 6%.
The results of modeling the load characteristics of the equivalent thermoEMF sources obtained by parallel
connection of different quantities of two types of thermocouples are presented. It is shown that in order to obtain
reliable data, it is necessary to provide an equivalent source load of at least 1 kOhm.
Description
Citation
Simulation of multipoint contact under thermoelectric testing/Kostina M.A. [et al.] // Eurasian Physical Technical Journal. – 2024- Vol.21 - № 1(47). – pp.93-103.